The Alpha Evoke 28 is a high-efficiency condensing combination boiler designed for wall-mounted installation. It features electronic ignition and a modulating fan for optimal performance.

1.1 Overview of the Alpha Evoke 28 Boiler

The Alpha Evoke 28 is a wall-mounted, room-sealed, gas-fired, high-efficiency condensing combination boiler. Designed for residential use, it offers a compact and lightweight design, making it ideal for installation in smaller spaces. The boiler features a stainless steel heat exchanger and advanced combustion technology to ensure reliable performance. It is compatible with both natural gas and LPG, providing flexibility for different fuel sources. The Alpha Evoke 28 is known for its energy efficiency, modulating heat output, and electronic ignition system, making it a popular choice for modern heating systems.

1.2 Key Features of the Alpha Evoke 28 Boiler

The Alpha Evoke 28 boiler stands out for its high-efficiency condensing technology, achieving excellent energy savings. It features a modulating fan and gas valve, allowing precise heat output adjustment. The boiler includes a stainless steel heat exchanger for durability and a Grundfos Hydroblock assembly for efficient water circulation. Its lightweight design, combined with a compact size, simplifies installation. Additionally, the boiler offers a user-friendly control panel with clear settings for temperature and operational modes, ensuring easy management of heating and hot water needs.

Installation and Servicing Instructions

The Alpha Evoke 28 boiler requires careful installation and regular servicing to ensure optimal performance; Follow the provided guidelines for wall mounting, venting, and step-by-step instructions.

2.1 Wall Mounting and Venting Requirements

The Alpha Evoke 28 boiler must be wall-mounted in a well-ventilated area, adhering to room-sealed and fan-assisted installation guidelines. Ensure proper clearance is maintained around the boiler for safe operation. The venting system must comply with local gas safety regulations to prevent any hazards. Always follow the manufacturer’s instructions for securing the boiler to the wall and connecting the flue system correctly. Proper installation is crucial for efficient performance and to meet safety standards.

2.2 Step-by-Step Installation Guidelines

To install the Alpha Evoke 28, begin by securing the wall mounting bracket according to the manufacturer’s specifications. Next, connect the flue system, ensuring it meets local gas safety regulations. Carefully lift and mount the boiler onto the bracket, ensuring it is level. Connect the gas supply line, water pipes, and electrical connections as outlined in the manual. Finally, test the system for leaks and proper operation. Always refer to the manual for detailed steps and comply with safety standards.

Operating the Alpha Evoke 28 Boiler

The Alpha Evoke 28 operates with electronic ignition and heat output modulation, ensuring efficient performance; The modulating fan and gas valve optimize energy use and heating control.

3.1 Electronic Ignition and Heat Output Modulation

The Alpha Evoke 28 features electronic ignition, eliminating the need for a pilot light and enhancing safety. Its heat output modulation adjusts automatically, optimizing energy efficiency.

The modulating fan and gas valve work together to regulate combustion, ensuring consistent heating while reducing fuel consumption. This system adapts to demand, maintaining precise temperature control.

These advanced features contribute to lower energy bills and reduced emissions, making the boiler environmentally friendly and cost-effective for home heating needs.

3.2 Understanding the Control Panel and Settings

The Alpha Evoke 28 control panel offers intuitive operation with clear displays for temperature settings and system status. Users can adjust central heating and domestic hot water temperatures easily.

The panel also provides diagnostic information and error codes, aiding in quick troubleshooting. Familiarizing yourself with these settings ensures optimal performance and energy efficiency.

Regularly reviewing and adjusting these settings helps maintain comfort and reduces energy consumption. Understanding the control panel is essential for effective boiler management.

Maintenance and Servicing

Regular servicing ensures the Alpha Evoke 28 operates efficiently and safely. Annual professional checks are recommended to maintain warranty validity and performance.

4;1 Regular Maintenance Requirements

Regular maintenance is crucial for the Alpha Evoke 28 boiler to ensure optimal performance and longevity. This includes annual servicing by a qualified engineer, checking the heat exchanger, and cleaning the condensate trap. Users should also inspect the flue for blockages and ensure all components are free from corrosion. Additionally, the system should be bled to remove airlocks, and the pressure gauge should be checked to maintain the recommended pressure level. These steps help prevent breakdowns and maintain efficiency year-round.

4.2 Servicing Checklists for Optimal Performance

To ensure the Alpha Evoke 28 boiler operates efficiently, a professional servicing check is required annually. This includes inspecting the heat exchanger, burner, and flue for damage or blockages. The condensate trap should be cleaned, and the system’s water pressure checked. Additionally, the gas valve and ignition system must be tested for proper function. Ensuring all components are in good condition helps maintain reliability, efficiency, and safety. Always follow the manufacturer’s guidelines for servicing procedures.

Troubleshooting Common Issues

This section addresses frequent problems like error codes, low pressure, and ignition faults, providing clear solutions to restore your Alpha Evoke 28 boiler to optimal operation.

5.1 Identifying Common Faults and Error Codes

The Alpha Evoke 28 boiler may display error codes such as E1, E2, or E3, indicating issues like low water pressure, faulty sensors, or ignition problems. These codes help diagnose faults quickly. Users should refer to the manual for specific code meanings and solutions. Common faults include no heat output, leaks, or erratic burner behavior. Checking gas supply, water pressure, and sensor functionality can often resolve these issues. Always consult the troubleshooting guide before attempting repairs;

5.2 Resetting the Boiler and Diagnostic Procedures

To reset the Alpha Evoke 28 boiler, press and hold the reset button for 3-5 seconds until the display indicates normal operation. If issues persist, perform diagnostic checks by verifying gas supply, water pressure, and sensor functionality. Consult the manual for specific error code solutions. Always ensure the boiler is cool before attempting internal inspections. If diagnostics fail, contact a qualified technician to avoid further complications. Regular maintenance can prevent recurring faults and ensure optimal performance.

Safety Considerations

Ensure proper ventilation and room sealing to prevent carbon monoxide risks. Regularly inspect gas connections and follow emergency shutdown procedures. Always adhere to manufacturer guidelines.

6.1 Room Sealing and Gas Safety Precautions

Proper room sealing is essential to prevent carbon monoxide buildup. Ensure adequate ventilation and avoid obstructing air vents. Regularly inspect gas connections for leaks or damage. In case of a gas leak, immediately shut off the supply and ventilate the area. Never restart the boiler without professional verification. Always follow gas safety guidelines to maintain a safe operating environment and prevent potential hazards. Adhere strictly to manufacturer recommendations for installation and maintenance.

6.2 Emergency Shutdown Procedures

In case of an emergency, switch off the boiler’s power supply immediately. Close the main gas valve to halt fuel flow. Open windows for ventilation if gas is suspected. Do not attempt to restart the boiler without professional inspection. If a gas leak is detected, evacuate the area and contact a qualified technician. Always follow the manufacturer’s emergency shutdown guidelines to ensure safety and prevent potential hazards. Regular servicing can help identify and address issues before they escalate.

Technical Specifications

The Alpha Evoke 28 is a wall-mounted, condensing combination boiler with a stainless steel heat exchanger, designed for high efficiency and compact installation. Dimensions are optimized for space-saving.

7.1 Dimensions and Weight of the Alpha Evoke 28

The Alpha Evoke 28 boiler measures 700mm in height, 400mm in width, and 250mm in depth, making it compact for wall-mounted installations. It weighs approximately 28.5kg, ensuring easy handling during installation. The lightweight design is due to its high-efficiency stainless steel heat exchanger, which is moulded in thermoplastic for durability and reduced weight. These dimensions and weight make it ideal for space-saving installations while maintaining robust performance and energy efficiency.

7.2 Fuel Types and Efficiency Ratings

The Alpha Evoke 28 boiler is compatible with both natural gas (NG) and liquefied petroleum gas (LPG), offering flexibility for various installations. It boasts a high efficiency rating with an ErP A-rating for heating and hot water, ensuring low energy consumption and reduced emissions. The boiler features a stainless steel heat exchanger and a Grundfos hydroblock with variable speed operation, contributing to its high efficiency and reliability. This makes it an eco-friendly and cost-effective choice for homeowners.

Downloading the User Manual

The Alpha Evoke 28 user manual is freely downloadable in PDF format from various online platforms, ensuring easy access to installation and servicing instructions.

8.1 Availability of PDF Manuals Online

The Alpha Evoke 28 boiler manual is widely available online in PDF format, accessible through platforms like Gas 101, ManualsLib, and Alpha’s official website. Users can download the manual without registration, ensuring easy access to installation, servicing, and troubleshooting guidelines. The PDF format allows for offline viewing and printing, making it convenient for technicians and homeowners. Multiple sources offer the manual free of charge, including model-specific instructions for the Alpha Evoke 28, 28 LPG, and 33 versions. This ensures comprehensive coverage for all variants.

8.2 Instructions for Downloading and Saving the Manual

To download the Alpha Evoke 28 manual, visit websites like Gas 101 or ManualsLib. Locate the boiler model, click the download link, and save the PDF to your device. Ensure you select a trusted source to avoid unauthorized content. Once downloaded, open the file using a PDF reader to access installation, servicing, and troubleshooting details. For convenience, save the manual in a dedicated folder for future reference. This ensures easy access to critical information when needed.

The Alpha Evoke 28 Boiler is a reliable, high-efficiency condensing combination boiler designed for wall-mounted installation; Its electronic ignition and modulating heat output ensure optimal performance. With proper installation, servicing, and maintenance, it provides consistent heating and hot water. Referencing the user manual is essential for troubleshooting and ensuring longevity. By following the guidelines outlined, users can maximize the boiler’s efficiency and safety. Downloading and saving the manual ensures easy access to critical information whenever needed.

Leave a Reply